<ErrorNumber>43032</ErrorNumber>
<ErrorFamily>Debris Removal</ErrorFamily>
<ErrorMessage>
DEB: The particulate filter is almost full AND the chemical filter has almost expired
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Both the chemical and particulate filters are almost full.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Cause 1:  The particulate filter is almost full AND the chemical filter is almost full.
Solution: Order both chemical and particulate filters so they are on hand when they expire.  See the label on the back of the cabinet or the user manual or the filter itself for the filter part number.  No need to change either filter until the actual particulate or chemical filter full message is displayed.
-Note: Once a filter is full you can not image plates until it is replaced.
</Cause>
<LastModified>
07-Jul-2001
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:36 2008 PST
</Updated>
<Links>
</Links>
</Error>